Lumit® IFN-γ (Human) Immunoassay
No-Wash Immunoassay for IFN-γ Detection
- Fast add-and-read protocol performed directly on cells
- Luminescent detection with just a plate-reading luminometer
- Scalable to 96- or 384- well plates, protocols included
- Pack sizes show assay number for 96-well plates
Catalog Number:
Choose a product
Size
Catalog Number: W6040
Catalog Number: W6042
Catalog Number: W6041
Catalog Number: W134A-C
Quantify Cytokine Release Without Tedious Wash Steps
The Lumit® IFN-γ Immunoassay quantitatively measures released IFN-γ in cell culture samples using a simple, no-wash protocol. Just add labeled antibodies to the sample, add detection reagent and read luminescent signal using a standard plate-reading luminometer. The entire protocol is completed in less than 70 minutes! The assay can be used directly on cells in culture or culture medium transferred to a separate assay plate.
Note: The total number of assays per kit will vary based on final well volume.
For standard well volumes:
- 100 assay kits: applicable for 100 assays in 96-well plates or 400 assays in 384-well plates.
- 500 assay kits: applicable for 500 assays in 96-well plates or 2,000 assays in 384-well plates.
- 1,000 assay kits: applicable for 1,000 assays in 96-well plates or 4,000 assays in 384-well plates.
How the Lumit® IFN-γ Immunoassay Works
Primary antibodies to IFN-γ were selected for their specific and sensitive detection and labeled with the LgBiT and SmBiT subunits of NanoBiT® Luciferase. In the presence of IFN-γ, the subunits are brought together to form an active luciferase enzyme. Addition of optimized substrate generates a bright luminescent signal proportional to IFN-γ levels.
Simple One-Plate Protocol, No Wash Steps
Lumit™ 検出法の広いダイナミックレンジ
Lumit™ 検出のピコモルからナノモルのリニアレンジは、ほとんどの細胞モデルで予想される濃度をカバー。
|
Assay |
IFN-γ Human Immunoassay |
|
|
Limit of Detection (LOD) |
1.7pg/ml (3 SD above background) |
|
|
Dynamic Range |
7.3pg/ml – 10ng/ml |
|
|
Minimal Detectable Dose (MDD) |
1.1pg/ml (2 SD above background) |
|
|
Assay Time |
70 minutes |
|
|
Sample Type |
Cell culture supernatants |
|
SD=Standard Deviation
Detect IFN-γ as a Marker of T Cell Activation
Purified CD8+ T cells (effector cells) were combined with Raji B cells (target cells) and a serial dilution of Blincyto® (CD3 and CD19 bispecific T cell engager). The Lumit® IFN-γ (Human) Immunoassay reagents were added directly to treated cell wells to detect IFN-γ release from the T cells.
Multiple Cytokine Detection by Split-Sample Analysis
Human PBMCs were plated in a 96-well plate in 100µl and treated for 24 hours with cell stimulation cocktail (CSC), lipopolysaccharide (LPS) or R848. Four 20μl aliquots were transferred to a 384-well plate for detection of IL-2, IL-6, IFN-γ and TNF-α with the corresponding Lumit® Cytokine Immunoassay. This simple approach for profiling cytokine release can be applied to multiple cell models.
Explore Additional Cytokine Detection Assays
We offer a growing portfolio of assays to detect cytokines in cell culture samples.
Can’t find your target in the list?
Please enquire about early access to new assays in development.
For a biotech that understands time is of significant value, the Lumit® Immunoassays are an essential way for us to gather reliable data fast so that we can reach conclusions and make decisions sooner.
Jonathan Chow, Principal Scientist, Corner Therapeutics
Featured Application Note
CAR T cell-mediated cytotoxicity and cytokine release in response to antigen expression on target cells
Explore a multiplexing approach that unlocks the full potential of CAR T cell therapy with our Lumit® IFN-γ and TNF-α (Human) Immunoassays.
Protocols
Complete Protocol
Specifications
Catalog Number:
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Detection Substrate B |
VB405A | 1 × 160μl |
Lumit® Detection Buffer B |
VB406A | 1 × 3.2ml |
Lumit® Human IFN-ɣ Standard |
W134A-C | 1 × 25μl |
Anti-hIFN-γ mAb-SmBiT, 500X |
W135A | 1 × 30μl |
Anti-hIFN-γ mAb-LgBiT, 500X |
W136A | 1 × 30μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Detection Substrate B |
VB405A | 5 × 160μl |
Lumit® Detection Buffer B |
VB406A | 5 × 3.2ml |
Lumit® Human IFN-ɣ Standard |
W134A-C | 1 × 25μl |
Anti-hIFN-γ mAb-SmBiT, 500X |
W135A | 5 × 30μl |
Anti-hIFN-γ mAb-LgBiT, 500X |
W136A | 5 × 30μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Detection Substrate B |
VB405B | 1 × 1.25ml |
Lumit® Detection Buffer B |
VB406B | 1 × 25ml |
Lumit® Human IFN-ɣ Standard |
W134A-C | 1 × 25μl |
Anti-hIFN-γ mAb-SmBiT, 500X |
W135B | 1 × 300μl |
Anti-hIFN-γ mAb-LgBiT, 500X |
W136B | 1 × 300μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Human IFN-ɣ Standard |
W134A-C | 1 × 25μl |
Resources
その他
- Rapid and Sensitive Determination of Cytokine Release from Cells Without Sample Transfer
- Blog Article: Understanding Inflammation: A Faster, Easier Way to Detect Cytokines in Cells
- Blog Article: The Cytokine Storm: Why Some COVID-19 Cases are More Severe
- White Paper: Lumit® Immunoassays: A Rapid and Sensitive Method for Analyte Detection
- Application Note: Automated Lumit™ IFN-γ (Human) Immunoassay on the Hamilton Microlab STARlet
Related Products
類似製品
Lumit® IL-2 (Human) Immunoassay
Quantitatively measures released IL-2 in cell culture samples using a simple, no-wash protocol.
W6020, W6022, W6021, W122A-C
Lumit® IL-10 (Human) Immunoassay
Quantitatively measures released IL-10 in cell culture samples using a simple, no-wash protocol.
W6070, W6072, W6071, W131A-C
Lumit® IL-12 p70 (Human) Immunoassay
Quantitatively measures released IL-12 in cell culture samples using a simple, no-wash protocol that can be completed in 70 minutes or less.
W1850, W1851, W1852, W185A-C
Lumit® TNF-α (Human) Immunoassay
Quantitatively measures released TNF-α in cell culture samples using a simple, no-wash protocol.
W6050, W6052, W6051, W137A-C
関連製品
T Cell Activation Bioassay (NFAT/IL-2)
TCR/CD3 を介した T細胞活性化のためにデザインされたバイオロジックスの活性評価のために IL-2 または NFAT の2キットから選択可能
J1621, J1625, J1601, J1651, J1655, J1631
CellTox™ Green Cytotoxicity Assay
細胞死に伴う細胞膜破壊により細胞毒性を蛍光で測定
G8741, G8742, G8743, G8731
Lumit® Immunoassay Labeling Kit and Detection Reagents
Lumit®イムノアッセイ開発のための抗体標識キットと検出試薬
VB2500, VB2010, VB2020, VB2030, VB4050, VB4060
GloMax® Discover System
発光・蛍光・吸光度測定に対応した高性能マイクロプレートリーダー
GM3000