Paradyme™ 27GY STR System
The First STR Multiplex with Reduced-Stutter Polymerase
- Amplify all loci in the expanded CODIS core loci, including 23 autosomal STRs, 3 Y-STRs (DYS391, DYS570, DYS576) and Amelogenin, plus internal quality indicators (QIS and QIL)
- Reduced-Stutter Polymerase (RSP) minimizes stutter at the chemistry level, simplifying mixture interpretation and revealing minor contributor alleles in stutter positions of major profile peaks
- An 8-dye multiplex design minimizes amplicon size for increased performance with degraded and challenging samples
- High sensitivity for casework, generating complete profiles from low amounts of template DNA
Catalog Number:
Choose a product
Size
Catalog Number: RS2705
Catalog Number: RS2720
Catalog Number: DG5050
Catalog Number: DM1701
Clearer Profiles for Confident Mixture Interpretation
The Paradyme™ 27GY STR System provides all of the materials needed for co-amplification and 8-color fluorescent detection of 27 loci, including the expanded CODIS core loci, three Y-STR loci (DYS391, DYS570 and DYS576) and Amelogenin for gender determination. The 8-dye chemistry enables shorter amplicons, with all loci below 400bp, increasing the likelihood of generating informative profiles from degraded samples.
The system incorporates Reduced-Stutter Polymerase (RSP) that limits stutter artifact formation before interpretation begins. Clearer electropherograms simplify both human review and software-driven mixture analysis:
- Determination of the Number of Contributors (NoC) is faster and more accurate.
- Minor contributor alleles in the stutter positions of a major profile become visible.
- Interpretation is more consistent from analyst to analyst.
Two internal quality indicators, QIS (small) and QIL (large), provide sample-level assessment of amplification performance, helping analysts distinguish between inhibited and degraded samples to choose the right path forward without unnecessary rework.
Promega forensic products are manufactured in alignment with the ISO 18385 standard. This standard ensures minimal risk of human DNA contamination for products used to collect, store and analyze biological materials for forensic purposes. Learn more.
Superior Mixture Interpretation and NoC Estimation
Three-Person Mixture
Non-RSP System vs. Paradyme™ 27GY STR System
Two-Person Mixture
Non-RSP System vs. Paradyme™ 27GY STR System
In a comparison study of the Paradyme™ 27GY STR System and a non-RSP 6-dye STR kit, six former DNA analysts analyzed 20 mixtures of up to five contributors. Analysts had varying levels of experience (5–20 years) and were blinded to the number of contributors. Across all analysts and samples, Paradyme™ 27GY STR System demonstrated higher interpretation accuracy, reduction in interpretation time, and higher analyst confidence.
| Metric | Paradyme™ 27GY STR System | Non-RSP 6-Dye Kit |
|---|---|---|
| Overall NoC Accuracy | 88% (79/90) | 49% (43/87) |
| Average Interpretation Time per Sample | 7.0 minutes | 12.4 minutes |
| Average Analyst Confidence (1–5 scale) | 4.5 | 3.7 |
Excellent Sensitivity for Low-Template Samples
The Paradyme™ 27GY STR System reliably produces complete STR profiles from low amounts of template DNA, calling 100% of expected alleles down to 62pg and approximately 95% of alleles at 31pg.
Seven replicate PCR amplifications of 1.0ng, 0.5ng, 0.25ng, 0.125ng, 0.0625ng, 0.03125ng and 0.015625ng purified human DNA were amplified on a ProFlex thermal cycler using the recommended cycling protocol. Amplification products were electrophoresed on a Spectrum CE System. Percent allele calls at each template amount is plotted on the Y axis.
Reduced Stutter Makes Probabilistic Genotyping Better
Probabilistic genotyping (PG) software does not remove stutter; it models expected stutter behavior at each locus and weighs whether each small peak is stutter or a true allele. Every ambiguous peak weakens the resulting statistics. Because RSP reduces stutter before interpretation, less stutter needs to be modeled probabilistically—cleaner data in, better statistics out.
PG results are also more accurate when the assumed contributor count is correct—Paradyme™ 27GY STR System demonstrated substantially more accurate NoC determination in a blind evaluation study.
Developed for Spectrum CE Systems
Promega’s 8-dye chemistry was developed for the Spectrum CE family, with a size for any laboratory throughput:
- Spectrum Compact CE System (4 capillaries, up to 32 samples)
- Spectrum CE System, 8-Capillary (>1,500 samples per week)
- Spectrum CE System, 24-Capillary (>4,000 samples per week)
Eight-dye data can be analyzed with GeneMarker® HID Software for Spectrum CE Systems and FaSTR™ DNA software (PHF Sciences).
Protocols
Specifications
Paradyme™ 27GY STR System (Cat.# RS2705) provides sufficient reagents to perform 50 reactions of 25µl each, or 100 direct-amplification reactions of 12.5µl each. Cat.# RS2705 comprises Cat.# RS2706 (Box 1) and Cat.# RS2707 (Box 2); the components of each box are summarized in the bulleted list. Please note the separate storage temperatures for the two boxes.
Paradyme™ 27GY STR System (Cat.# RS2720) provides sufficient reagents to perform 200 reactions of 25µl each, or 400 direct-amplification reactions of 12.5µl each. Cat.# RS2720 comprises Cat.# RS2721 (Box 1) and Cat.# RS2722 (Box 2); the components of each box are summarized in the bulleted list. Please note the separate storage temperatures for the two boxes.
- Box 1 Pre-Amplification Components: RP704B, DW099A, DD710A. Store Box 1 at +2 to +10°C.
- Box 1 Post-Amplification Components: DG857A, DG895B. Store Box 1 at +2 to +10°C.
- Box 2 Pre-Amplification Components: RM300A, RT100A, RT110A. Store Box 2 at –30 to –10°C.
See the "What's in the box?" table for each size of the Paradyme™ 27GY STR System for more component details.
Catalog Number:
選択製品の構成品内容
| Item | Part # | Size | Concentration | Available Separately |
|---|---|---|---|---|
Paradyme™ 27GY 10X Primer Pair Mix |
RP704B | 1 × 125μl | ||
|
Water, Amplification Grade |
DW099A | 5 × 1,250μl | View Product | |
|
2800M Control DNA |
DD710A | 1 × 25μl | 10ng/μl | View Product |
CCO Internal Lane Standard 500 |
DG857A | 1 × 250μl | ||
Paradyme™ 27GY Allelic Ladder Mix |
DG895B | 1 × 25μl | ||
Paradyme™ 27GY 5X Master Mix |
RM300A | 1 × 250μl | ||
TCEP, Concentrated |
RT100A | 1 × 800μl | ||
TCEP Dilution Buffer |
RT110A | 1 × 1ml |
Patent Pending.
選択製品の構成品内容
| Item | Part # | Size | Concentration | Available Separately |
|---|---|---|---|---|
Paradyme™ 27GY 10X Primer Pair Mix |
RP704B | 4 × 125μl | ||
|
Water, Amplification Grade |
DW099A | 5 × 1,250μl | View Product | |
|
2800M Control DNA |
DD710A | 2 × 25μl | 10ng/μl | View Product |
CCO Internal Lane Standard 500 |
DG857A | 2 × 250μl | ||
Paradyme™ 27GY Allelic Ladder Mix |
DG895B | 4 × 25μl | ||
Paradyme™ 27GY 5X Master Mix |
RM300A | 4 × 250μl | ||
TCEP, Concentrated |
RT100A | 1 × 800μl | ||
TCEP Dilution Buffer |
RT110A | 1 × 1ml |
Patent Pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
8C Matrix Mix |
DG854A | 1 × 150μl |
Matrix Dilution Buffer |
DM145A | 5 × 200μl |
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Paradyme™ 27GY QI Reagent |
DM170A | 1 × 800μl |
Resources
技術記事
Software and Firmware
Related Products
類似製品
PowerPlex® Fusion 6C System
27ローカス同時増幅の6色蛍光検出システム
DC2705, DC2720, DC2780
PowerPlex® 35GY System
First 8-dye STR multiplex; allows co-amplification and fluorescent detection of the 20 CODIS core loci plus Amelogenin and DYS391 for sex determination.
DC3520, DG5010, DM1551, DG8571
PowerPlex® 18E System
First 8-color STR multiplex for European forensic laboratories; allows amplification and detection of all 16 ENFSI-recommended loci plus Amelogenin and DYS391 for sex determination.
DC3620, DG5010, DM1601, DG8571
関連製品
Spectrum CE System
A high-throughput capillary electrophoresis system for forensic and paternity labs.
CE1008
Spectrum Compact CE System
サンガーシーケンスとフラグメント解析可能、お手頃なベンチトップ機器
CE1304, CE1307, CE1305
PowerPlex® Matrix Standards
PowerPlex® Systemを使用するために用いる蛍光標識DNA断片
DG4800, DG4850, DG4900, DG5010
PowerQuant® System
5-color, 4-target probe-based qPCR assay.
PQ5002, PQ5008, DS1221