pFN31 and pFC32 NanoLuc® Protein Fusion Flexi® Vectors
Generate N- or C-Terminal Fusions to NanoLuc® Luciferase Reporter
- Insert protein of interest using the Flexi® Vector System
- Select options for N- or C-terminal NanoLuc® fusions and antibiotic resistance (ampicillin or kanamycin)
- Bright NanoLuc® reporter enables endogenous expression levels of fusion proteins for biologically relevant results
Vectors
| Catalog No. | Product Name | Size | Price | Qty | |||
|---|---|---|---|---|---|---|---|
| N1311 | pFN31A Nluc CMV-Hygro Flexi® Vector | View Specifications | 20μg | Please Enquire | |||
| N1321 | pFN31K Nluc CMV-neo Flexi® Vector | View Specifications | 20μg | Please Enquire | |||
| N1331 | pFC32A Nluc CMV-Hygro Flexi® Vector | View Specifications | 20μg | Please Enquire | |||
| N1341 | pFC32K Nluc CMV-neo Flexi® Vector | View Specifications | 20μg | Please Enquire |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
NanoLuc®タンパク質融合ベクターで目的タンパク質とNanoLuc®を簡単に融合させることができます。また、クローニング方法の好みによって2種類のベクターから選べます。
• pNLF Vectorシリーズ:目的タンパク質のN末端かC末端にNluc全長を、あるいはN末端に分泌型Nlucを融合するためのベクターです。マルチクローニングサイトを使用した従来通りの方法でクローニングが可能です。
• pF Vectorシリーズ:Flexi® Vector Cloning Systemを利用して、目的タンパク質のN末端かC末端にNluc全長を融合するためのベクターです。Flexi® Vector Cloning Systemはレアカッター制限酵素であるSgfIとPmeIを使用し、インサートの方向性、読み枠を維持したまま効率よくクローニングやFlexi®ベクター間の移変えを行えるシステムです。
- 発現量の測定が簡便:Nano-Glo® Luciferase Assay System 試薬を添加するとNanoLuc® 融合タンパク質から発光シグナルが得られ、細胞内タンパク質レベルを測定可能
- より生物学的妥当性のある結果を:NanoLuc®レポーターは非常に明るいため、内在性レベルでのNanoLuc® 融合タンパク質発現が可能で、過剰発現によるアーティファクトを回避
- 細胞内タンパク質の可視化:細胞毒性の原因となる励起光の照射は不要
- BRETに好適:青にシフトした明るいNanoLuc®の蛍光スペクトラムにより、より良いシグナル・バックグラウンド比とダイナミックレンジを実現
- 選べるクローニング方法:従来のクローニング法とFlexi® Cloning systemを選択可能
- 安定発現株作製可能:全てのベクターに安定発現株作製用の選択マーカーを導入
- 化合物スクリーニング
- タンパク質間相互作用解析
- タンパク質:低分子相互作用解析
- 生物発光イメージング
- タンパク質安定性
【ライセンス】NanoLuc
【Q&A】Reporter_1.
- Hall, M.P. (2012) Engineered luciferase reporter from a deep sea shrimp utilizing a novel imidazopyrazinone substrate. ACS Chemical Biology 7(11), 1848–57.
Vector Maps and Sequence Information
pFN31A Nluc CMV-Hygro Flexi® Vector GenBank® Accession Number KF793052 and vector sequence text file.
pFN31K Nluc CMV-neo Flexi® Vector GenBank® Accession Number KF793053 and vector sequence text file.
pFC32A Nluc CMV-Hygro Flexi® Vector GenBank® Accession Number KF811455 and vector sequence text file.
pFC32K Nluc CMV-neo Flexi® Vector GenBank® Accession Number KF811456 and vector sequence text file.
Protocols
No protocols available
Specifications
Catalog Number:
選択製品の構成品内容
| Item | Part # | Size | Concentration |
|---|---|---|---|
pFN31A Nluc CMV-Hygro Flexi® Vector |
N131A | 1 × 20μg | 0.1μg/μl |
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.
In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.
Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size | Concentration |
|---|---|---|---|
pFN31K Nluc CMV-neo Flexi® Vector |
N132A | 1 × 20μg | 0.1μg/μl |
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.
In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.
Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size | Concentration |
|---|---|---|---|
pFC32A Nluc CMV-Hygro Flexi® Vector |
N133A | 1 × 20μg | 0.1μg/μl |
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.
In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.
Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size | Concentration |
|---|---|---|---|
pFC32K Nluc CMV-neo Flexi® Vector |
N134A | 1 × 20μg | 0.1μg/μl |
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.
In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.
Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.
Resources
No related resources found
Related Products
類似製品
pNLF1 NanoLuc® Protein Fusion Vectors
目的タンパク質のN末端かC末端にNluc全長を、あるいはN末端に分泌型Nlucを融合するための3つのベクター
N1351, N1361, N1371
Transfection Carrier DNA
DNA 全体量を維持しつつ発現ベクターやレポーターベクター量を下げてトランスフェクションするための希釈用プラスミド DNA
E4881, E4882
NanoLuc® Stability Sensors for Cell Signaling
NanoLuc®ルシフェラーゼにキーとなる2つのシグナルタンパク質HIF1AとNRF2を融合し、シグナルイベントを直接測定することで融合タンパク質の安定性の検討
N1381, N1391
Coincidence Reporter Vectors
同じmRNA転写物からホタルルシフェラーゼとNanoLuc®の両方を発現するベクター(プロモーターの有無が選択可能)で、化合物による試験の際に偽陽性を最低限にできる
N1461, N1471, N1481, N1491
関連製品
Flexi® Cloning System
タンパク質コーディング領域を迅速、効率的、高い忠実度で移し換えるので再シークエンシング不要で、タンパク質コーディング配列の方向性を保つクローニング方法
C8640, C8820, C9320
Nano-Glo® Luciferase Assay System
NanoLuc® Luciferaseのための、添加・混和・測定アッセイ、ほとんどの実験でシグナル半減期2時間以上
N1110, N1120, N1130, N1150
FuGENE® HD Transfection Reagent
トランスフェクション困難な細胞株を含む広範な細胞腫に、より優れたパフォーマンス
E2311, E2312
GloMax® Discover System
発光・蛍光・吸光度測定に対応した高性能マイクロプレートリーダー
GM3000