Lumit® Anti-Tag Protein Interaction Reagents
Solution-Based Approach to Detect Protein Interactions of Tagged Proteins
- Fast and sensitive detection of protein interactions in 30–120 minutes
- No wash, transfer or immobilization steps
- Reagents are anti-tag antibodies (and streptavidin) that are conjugated with Lumit® LgBiT and SmBiT
- Tags include 6His, GST, DYKDDDDK (recognizes FLAG®), human IgG and biotin
- Application Notes available below
- These reagents are used with Lumit® Detection Reagent A
Catalog Number:
Choose a Product
Size
Catalog Number: W1600
Catalog Number: W1601
Catalog Number: W1611
Catalog Number: W1620
Catalog Number: W1621
Catalog Number: W1631
Catalog Number: W1640
Catalog Number: W1641
Catalog Number: W1651
Catalog Number: W1660
Catalog Number: W1661
Catalog Number: W1671
Catalog Number: CS332214
Catalog Number: CS332222
Catalog Number: CS332223
タグ付けされたタンパク質の相互作用 (PPI) を検出するスケーラブルなアッセイ試薬
Lumit™ Anti-Tag protein-protein interaction (PPI) immunoassay は、タグ付きタンパク質を利用してタンパク質間またはタンパク質小分子間の相互作用を測定するホモジニアス(無洗浄操作の)なアッセイシステムです。
このアッセイは、免疫検出と NanoLuc® バイナリーテクノロジー (NanoBiT) を組み合わせたもので、このNanoBiTは相互作用研究に理想的な構造相補性レポーターです。NanoBiT® システムは2つのサブユニットであるLarge BiT (LgBiT; 18kDa) と Small BiT (SmBiT; 11 アミノ酸からなるペプチド) で構成されています。これらのサブユニットは、リコンビナントフュージョンとして発現させたり、抗体や他の標的タンパク質と化学的に結合させることができます。LgBiTおよびSmBiTサブユニットは、弱い親和性(Kd = 190μM)を有し、安定性と最小限の自己会合性が得られるように最適化されています。LgBiTとSmBiTが近接すると、基質の存在下で発光する機能的な酵素を形成します。
Lumit®イムノアッセイのワークフロー
タンパク質タグを用いたLumit™ PPI Immunoassay では、ストレプトアビジンまたは6His、GST、FLAG®、ヒトFcに対する抗体がLgBiTまたはSmBiTで標識されています。異なるタグを持つ2つのタンパク質が結合すると、対応するSmBiTおよびLgBiT標識抗体を用いて相互作用を検出することができます。
GTP依存的な KRAS-cRAF 相互作用の検出
KRASは、GTPまたは非加水分解性アナログGppNHpと結合すると、下流のエフェクターcRAFと相互作用します。
Lumit™ PPIアッセイは、GTP結合状態のわずかな変化を検出する上で十分な感度を有しています。
VHLベースの三元複合体形成モニタリング
標的タンパク質に対す異なるPROTACの効力を比較することができます。三者複合体(Ternary Complex)の形成を測定するためのソリューションについて、詳しくご紹介します。
Protocols
Specifications
Catalog Number:
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-6His-LgBiT |
W160A | 1 × 20μl |
Lumit® Anti-6His-SmBiT |
W161A | 1 × 20μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-6His-LgBiT |
W160B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-6His-SmBiT |
W161B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-GST-LgBiT |
W162A | 1 × 20μl |
Lumit® Anti-GST-SmBiT |
W163A | 1 × 20μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-GST-LgBiT |
W162B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-GST-SmBiT |
W163B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-DYKDDDDK-LgBiT |
W164A | 1 × 20μl |
Lumit® Anti-DYKDDDDK-SmBiT |
W165A | 1 × 20μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-DYKDDDDK-LgBiT |
W164B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Anti-DYKDDDDK-SmBiT |
W165B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Streptavidin-LgBiT |
W166A | 1 × 20μl |
Lumit® Streptavidin-SmBiT |
W167A | 1 × 20μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Streptavidin-LgBiT |
W166B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
選択製品の構成品内容
| Item | Part # | Size |
|---|---|---|
Lumit® Streptavidin-SmBiT |
W167B | 1 × 200μl |
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
Recipient may use this material for research use only. No transfer or commercial use of this material is allowed. Commercial use means any and all uses of this material by a party in exchange for consideration, including, but not limited to,
- (1) use in further product manufacture; and
- (2) resale of the material, whether or not such material is resold for use in research. Notwithstanding the foregoing, recipient may use this material in provision of services, information or data to third parties in exchange for consideration, provided that recipient does not transfer the material. Recipient shall have no right to modify or otherwise create variations of the material. No other use of this material is authorized without the prior express written consent of Promega.
In addition, recipient must either:
- (a) use Lumit™-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this material; or
- (b) contact Promega to obtain a license for use of the material with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
Recipient may use this material for research use only. No transfer or commercial use of this material is allowed. Commercial use means any and all uses of this material by a party in exchange for consideration, including, but not limited to,
- (1) use in further product manufacture; and
- (2) resale of the material, whether or not such material is resold for use in research. Notwithstanding the foregoing, recipient may use this material in provision of services, information or data to third parties in exchange for consideration, provided that recipient does not transfer the material. Recipient shall have no right to modify or otherwise create variations of the material. No other use of this material is authorized without the prior express written consent of Promega.
In addition, recipient must either:
- (a) use Lumit™-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this material; or
- (b) contact Promega to obtain a license for use of the material with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lumit® Conjugated Reagents Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only. No transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; and (2) resale of the product, whether or not such product is resold for use in research. Notwithstanding the foregoing, researcher may use this product in provision of services, information or data to third parties in exchange for consideration, provided that researcher does not transfer the product. Researchers shall have no right to modify or otherwise create variations of the product. No other use of this product is authorized without the prior express written consent of Promega.
In addition, researcher must either:
(i) use Lumit®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(ii) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
Recipient may use this material for research use only. No transfer or commercial use of this material is allowed. Commercial use means any and all uses of this material by a party in exchange for consideration, including, but not limited to,
- (1) use in further product manufacture; and
- (2) resale of the material, whether or not such material is resold for use in research. Notwithstanding the foregoing, recipient may use this material in provision of services, information or data to third parties in exchange for consideration, provided that recipient does not transfer the material. Recipient shall have no right to modify or otherwise create variations of the material. No other use of this material is authorized without the prior express written consent of Promega.
In addition, recipient must either:
- (a) use Lumit™-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this material; or
- (b) contact Promega to obtain a license for use of the material with LARs not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Resources
No related resources available
Related Products
類似製品
Lumit™ イムノアッセイ用 細胞溶解剤、検出試薬、二次抗体
Lumit™ Immunoassay Cellular System の構成品 Lumit™ Immunoassay Lysis and Detection Kit reagents や Lumit™ 二次抗体など
W1021, W1022, W1031, W1032, W1041, W1042, W1051, W1052, W1061, W1062, W1231, W1232, W1233
NanoBRET® PPI Starter Systems
ライブセルPPIアッセイ:BRETベースの相互作用検出に必要なベクター、コントロール、検出試薬を含む
N1811, N1821
NanoBiT® PPI Starter Systems
生細胞でタンパク質相互作用の検出を行うための相補的レポーター
N2014, N2015, N2016
NanoBRET® VHL and CRBN Ternary Complex Starter Kits
生細胞における VHL または CRBNと標的タンパク質との三重複合体形成をBRETにより定量
ND2700, ND2720