QuantiFluor® ssDNA System

Part Numbers: E3190

E3190_QuantiFluor--ssDNA-System_3
customize-this-small

高感度、蛍光一本鎖DNA定量

  • 低濃度サンプルではNanoDropよりも高感度
  • 分光光度法よりもより少ないDNA量で測定可能

Size

選択製品のカタログ番号: E3190

Please Enquire
This product is discontinued
Request a Sample
Not available in all countries
This product is available under our Early Access program - Learn More
This product is available under our Catalog (FT) program - Learn More
QuantiFluor® ssDNA System
1ml
Your price:

シンプルで正確なssDNA 定量。希釈作業や余分なチューブは不要です。

QuantiFluor® ssDNA System は溶液中に含まれる少量の 1本鎖 DNA  (ssDNA) を高感度に定量できる蛍光色素を含みます。ssDNA の検出や定量は、 ssDNA ウイルスの研究、部位特異的変異導入のための合成 ssDNA プローブの定量、1本鎖 cDNA の分析あるいは DNA メチル化研究で用いるバイサルファイイト処理 DNA の定量など多くの分子生物学研究アプリケーションで有用です。

QuantiFluor® ssDNA System は他法 (1 µg) よりも少量の DNA (200pg)  を使用するので、下流のアッセイで使用するサンプルを節約することができます。

QuantiFluor ssDNA Kit

Improved Sensitivity vs. Absorbance and Other Fluorescent ssDNA Quantitation Systems

For low-concentration samples, sensitivity of the QuantiFluor® ssDNA System is significantly increased compared to absorbance at 260nm (NanoDrop® method) and Qubit® ssDNA.

The dynamic range of the assay is wider than that of Qubit® ssDNA and equivalent to OliGreen® reagent.

12116MB-W
Sample* Assay
QuantiFluor® ssDNA System
0.2–400ng/µl
0.2–400ng
Quant-iT™ OliGreen
0.2–400ng/µl
0.2–400ng
Qubit® ssDNA
1–200ng/µl
1–200ng
NanoDrop® 2000 Spectrophotometer
2–12,000ng/µl
2–12,000ng

*Based on 1µl sample input per assay. Quantitation of more dilute samples is possible using more input dsDNA per assay.


ssDNA Quantitation Sensitivity and Assay Linearity

The QuantiFluor® ssDNA System detects as little as 1ng/ml ssDNA in a 96-well microplate assay (corresponding to 1µl of a 200ng/ml starting sample). Detection limit is defined as greater than three standard deviations above background RFU. Sensitivity is equivalent to Quanti-IT™ OliGreen® reagent.

10995MC-W

Easy Setup on Microplate or Single-Tube Fluorometers

The QuantiFluor® ssDNA System includes all the necessary reagents to quickly set up and quantitate single-stranded DNA, and is easy to set up on microplate or single-tube fluorometers. The System is compatible with any fluorometer capable of measuring the appropriate fluorescence excitation and emission spectra. Compatible Promega fluorometers include:

Quantus Nucleic Acid Quantification Fluorometer

(Use Blue Channel Ex 460nm, Em 515–575nm)


How Do Fluorescent Dyes Compare to Other Quantitation Methods?

In these short videos, Promega Applications Scientist Doug Wiezorek explains how fluorescent dye-based methods compare to other popular quantification techniques. Check them out for some quick guidelines on choosing the right nucleic acid quantitation method for your needs.

UV-Absorbance vs Fluorescence

Fluorescence vs qPCR

製品仕様

選択製品の構成品内容

Item Part # Size Available Separately

20X TE Buffer (pH 7.5)

E260A 1 × 25ml View Product

QuantiFluor® ssDNA Dye, 200X

E284A 1 × 1ml

ssDNA Standard

E288A 1 × 100μg

分析証明書

Search by lot number

使用制限

For Research Use Only. Not for Use in Diagnostic Procedures.

保存条件

BB

パテントおよび免責条項

U.S. Pat. Nos. 8,598,198 and 9,206,474 and other patents and patents pending.

Let's find the product that meets your needs.

Talk to a Scientist

scientist-uk-manos

Manos

UK